One platform. Multiple benefits. The ARCHITECT ci8200 combines the ARCHITECT c8000 and the ARCHITECT i2000SR to provide clinical chemistry and immunoassay testing in a single integrated system. By delivering fast, high-quality STAT results, the ARCHITECT ci8200 allows for laboratories to handle complex workloads.
The ARCHITECT ci8200 integrated system provides laboratories a single testing module that is specifically designed to improve laboratory efficiency and turnaround time. The ARCHITECT ci8200 offers a maximum throughput of up to 1,400 tests per hour, including 1,200 clinical chemistry and 200 immunoassay tests. Featuring a load-up capacity of 365 samples with 35 priority positions, the ARCHITECT ci8200 has up to 146 refrigerated reagent positions plus Integrated Chip Technology (Na+, K+ and Cl-).
For in vitro diagnostic use only.
Description | |
Reaction Method | See c8000 and i2000SR specifications |
Maximum Throughput | Up to 1,400 tests/hour |
Sample Types | See c8000 and i2000SR specifications |
Sample Tubes | Height: 72-102 mm Diameter 9.6-16.1 mm |
Sample Cup | Yes (50 µl dead volume) |
Sample Capacity | 365 |
Sample Barcode Types | Code 39, Codabar, Interleaved 2 of 5, Code 128 |
Sample Result Storage | 50,000 |
Sample Volume | See c8000 and i2000SR specifications |
Automatic Dilution | Yes |
Sample Probe Carryover | ≤0.1 parts per million |
Reagent Capacity | Up to 146 refrigerated positions plus patented ISE (Na+, K+ and Cl-) |
Reagent Type | See c8000 and i2000SR specifications |
Reagent Onboard Stability | See c8000 and i2000SR specifications |
Calibration Frequency | See c8000 and i2000SR specifications |
Sample, Clot and Bubble Detection | Yes |
Reagent Pressure Monitoring | See c8000 and i2000SR specifications |
Sample Interference Measurement | Yes: Hemolysis, Icterus, and Lipemia |
System Control Center | 1 SCC, with color touchscreen monitor, keyboard and mouse |
Onboard Maintenance Records | Yes |
Online Error Code Help | Yes |
Host Interface | Bidirectional, serial RS-232 interface, host query option available |
Remote Diagnostics | AbbottLink |
Dimensions | 48" x 127" x 49" |
Weight | 2,447 lbs |
Electrical Requirements | See c8000 and i2000SR specifications |
Water Requirements | See c8000 and i2000SR specifications |
Heat Output* | See c8000 and i2000SR specifications |
Sample Loading | RSH + Carousel |
*Values provided represent the typical output in “Running” mode for the system processing module and sample handler. A maximum value of 389 BTU/hr was obtained for the System Control Center (SCC) using the ARCHITECT i2000SR as a representative system. Values obtained during an internal study. Data is on file with Abbott. | |
Note: Some of these specifications are based on the combination of the ARCHITECT c8000 and the ARCHITECT i2000SR. For accurate and complete specifications, please refer to the individual operations manual. |
Review a few details about the ARCHITECT ci8200 integrated system in the specifications sheet (PDF, 118 KB).
Diagnostics at Abbott offers a complete portfolio of integrated solutions including Core Laboratory, Molecular, Point of Care, Rapid Diagnostics and Transfusion Medicine.
Find the latest information in laboratory science, therapeutic areas and Abbott innovation.
Receive exclusive benefits and resources when you register to access to the Customer Portal.
Abbott's Representatives are ready to offer support, gather feedback, and answer any questions.
Links which take you out of Abbott worldwide websites are not under the control of Abbott, and Abbott is not responsible for the contents of any such site or any further links from such site. Abbott is providing these links to you only as a convenience, and the inclusion of any link does not imply endorsement of the linked site by Abbott. The website that you have requested also may not be optimised for your screen size.
Please be aware that the website you have requested is intended for the residents of a particular country or countries, as noted on that site. As a result, the site may contain information on pharmaceuticals, medical devices and other products or uses of those products that are not approved in other countries or regions.